LV 2 Modules | HV 2 Modules | LV 3 Modules | HV 3 Modules | |
---|---|---|---|---|
Capacity (pump model) | 8 On-Board 8F | 12 On-Board 8F | ||
Input voltage | 180 - 253 VAC | 342 - 506 VAC | 180 - 253 VAC | 342 - 528 VAC |
Line frequency | 50 / 60 Hz | |||
Phase | 3 | |||
Nominal input power | 12 kW @ 60 Hz 10 kW @ 50 Hz | 18 kW @ 60 Hz 15 kW @ 50 Hz | ||
Nominal power factor | 0.9 | 0.85 | 0.9 | 0.85 |
Rated full load / locked rotor current | 39 / 170 | 18 / 83 | 58 / 255 | 24 / 125 (480 V 60 Hz, 380 V 50 Hz) 27 / 125 (480 V 50 Hz, 380 V 60 Hz) |
Maximum inlet temperature | 90°F (32°C) | |||
Minimum inlet temperature | 50°F (10°C) | |||
Flow rate | 5.50 ± 2.50 gpm (20.8 ± 9.5 lpm) | 8.25 ± 3.75 gpm (31.2 ± 14.2 lpm) | ||
Pressure drop (inlet-to-outlet) | 10.5 psi (0.72 bar) @ 5.5 gpm (20.8 lpm) | 10 psi (0.69 bar) @ 8.25 gpm (31.2 lpm) | ||
Maximum inlet pressure | 100 psi (6.9 bars) | |||
Alkalinity | 6.0 - 8.0 pH | |||
Calcium carbonate | < 75 ppm | |||
Input power cable (Customer supplied) | Rated 600 VAC 3 conductor cable with ground Check local electrical codes | |||
Ambient operating temperature range | 50 - 100ºF (10 - 38ºC) | |||
Gas supply connector | 3/4 in. Aeroquip self-sealing coupling, male thread | |||
Gas return connector | 3/4 in. Aeroquip self-sealing coupling, female thread | |||
Adsorber service schedule | Replace every 3 years | |||
Weight | 640 lbs / 290 kg | 650 lbs / 295 kg | 820 lbs / 372 kg | 830 lbs / 376 kg |